• roof mounted exhaust vent,ridge ventilator,natural roof ventilation-[MCWELL]
  • roof mounted exhaust vent,ridge ventilator,natural roof ventilation-[MCWELL]

Roof Mounted Exhaust Vent

The roof mounted exhaust vent can be installed on roof's ridge and slope, and the ventilation volume is large. The overall design is streamlined arc type, which not only ensures the strength of the ridge ventilator's body, but also effectively reduces the wind pressure on the natural roof ventilation's body. It is characterized by the large volume formed by the height of the roof ridge vent's body and the streamlined shape, which can effectively improve the indoor air collection and discharge capacity. A baffle plate (which can also be used as an opening and closing valve plate) is set to guide the hot air generated in the room, form a bottom-up boost to the ridge ventilator, and guide the heat-gathering air to be discharged upward.

 Advantages:

  1. Large throat and effective vents, high ventilation efficiency

  2. Adopt the patented technology of “holistic waterproof structure”, no leakage hazard

  3. Professional rainproof diversion system, good rainproof performance

  4. The rainproof board can be set as a daylighting board, which has the triple performance of ventilation, firefighting and smoke exhaust, and daylighting

  5. The frame has been calculated by structural load to ensure that it meets the requirements of wind, snow load and seismic grade at the location of the project, and has good structural stability and safety

 

 Common Specifications:

Ventilator code

Throat width(mm)

Throat length(mm)

Ventilator height(mm)

MCW5H(Z)—1530n
MCW5H(Z)—1540n

1500

3000*n、4000*n

1500

MCW5H(Z)—2030n
MCW5H(Z)—2040n

2000

3000*n、4000*n

2000

MCW5H(Z)—2530n
MCW5H(Z)—2540n

2500

3000*n、4000*n

2500

MCW5H(Z)—3030n
MCW5H(Z)—3040n

3000

3000*n、4000*n

3000

MCW5H(Z)—3530n
MCW5H(Z)—3540n

3500

3000*n、4000*n

3500

MCW5H(Z)—4530n
MCW5H(Z)—4540n

4500

3000*n、4000*n

4500

MCW5H(Z)—5030n
MCW5H(Z)—5040n

5000

3000*n、4000*n

5000

MCW5H(Z)—6030n
MCW5H(Z)—6040n

6000

3000*n、4000*n

6000

MCW5H(Z)—9030n
MCW5H(Z)—9040n

9000

3000*n、4000*n

9000

The roof ridge vent’s size can be customized according to client’s requirement.

 Scope of Application:

The roof mounted exhaust vent is suitable for steel structure buildings and large-scale public buildings.